FEATURES:
★ Modes & protection
With CC/CV/CP/CR/DYNA/List/OCP and other test modes.
★ Single machine automatic test:
The load effect, ripple, transient, OCP, short circuit and other tests are completed with one key to improve the test efficiency.
Complete test report and support manual single-step loading to support convenient maintenance application.
★ Synchronous timing control:
It supports synchronous loading, dynamic operation and List operation of 16-way load to meet the test requirements of multi-channel output power supply.
It supports parallel operation of 16-way loads and intelligent power distribution to meet the needs of high-power expansion.
★ High-speed loop (10us full scale current rise time):
The offset impact energy is reduced, the impact resistance is stronger, and the system reliability is higher.
The power ripple suppression ratio is higher and the load is more accurate.
★ High-speed and high-precision control and measurement:
0.03% control accuracy, 500kHz control frequency, programmable current change slope.
500kHz sampling, 15Hz data refresh rate, 0.03% accuracy, 10uA, 100uV stable resolution.
Real-time measurement of peak value and peak value of voltage and current (Vpp/Vp+/Vp -/Ip/Ip+/Ip -).
★ Dynamic load and control:
Maximum 50 kHz dynamic load working frequency, programmable current change slope, voltage peak Vp+/Vp - real-time measurement.
Synchronous timing control, supporting synchronous dynamic load of different loads.
Up to 50kHz automatic frequency conversion dynamic scanning function (Sweep).
★ Programmable load timing function (List):
8 files, each with 200 steps of load sequence, 2us resolution, and up to 50kHz complex waveform editing.
Single-step programmable current change rate and automatic polyline support make waveform editing more convenient and informative.
Synchronous timing control, supporting synchronous sequence loading of different loads.
★ Automatic OCP test:
Automatically grab OCP protection points.
Automatically grab * * power point (Pmax) and working voltage and current at this point.
★ Trigger and time measurement (Timing):
Triggering of voltage and current waveform, supporting power supply establishment time, OCP delay time, fuse on-off time and other tests.
External hardware trigger, support power start time/hold time and other tests.
Waveform capture, support OVP protection point and protection time test.
★ Program-controlled application:
Standard SCPI protocol, standard isolated RS232 serial port, maximum baud rate 115200.
5V/200mA isolated power output facilitates the interconnection of different interface devices (such as RS485 bus).
TRIG_ IN、RI、DFI、TRIG_ OUT four-channel high-speed isolated I/O signal supports synchronous application between different devices.
The fastest 2us sampling interval, 4096 points, 16-bit precision digital transient waveform output function.
TECHNICAL DATA
Model | JT6310A | ||
Input Rating | Power | 120W | |
Voltage | 0~15V | 0~150V | |
Current | 0~3A | 0~20A | |
Min. operating voltage | 1V@60A | ||
CC Mode | Range | 0~3A | 0~20A |
Resolution | 0.05mA | 0.5mA | |
Accuracy | 0.03%+0.08%FS | ||
CV Mode | Range | 0~15V | 0~150V |
Resolution | 0.2mV | 2mV | |
Accuracy | 0.03%+0.03%FS | ||
CP Mode | Range | 120W | |
Resolution | 16Bits | ||
Accuracy | 0.1%+0.1%FS | ||
CR Mode | Range | 0.05Ω~50KΩ | |
Resolution | 16Bits | ||
Accuracy | 0.1%+0.0001R | ||
LED Mode | Bandwidth | 100kHz above | |
Rd Coefficient Range | 0.001~1 | ||
Dynamic Operation Mode | Range | 10uS~50S | |
Resolution | 2uS | ||
Accuracy | 1uS+20PPM | ||
Slew rate | 0.6A/mS~3A/uS | ||
Voltage Meas. | Range | 0~15V | 0~150V |
Resolution | 0.1mV | 1mV | |
Accuracy | 0.02%+0.03%FS | ||
Current Meas. | Range | 0~3A | 0~20A |
Resolution | 0.01mA | 0.1mA | |
Accuracy | 0.015%+0.08%FS | ||
Ripple Meas. | Range | 0~15V | 0~150V |
Bandwidth | 15Hz~250kHz | ||
Accuracy | 0.03%+1mV | 0.03%+10mV |